Feature:
1. Constant Power Design: Wide range of use, allowing users to provide higher voltage and higher current flexible configuration within the rated power range.
2. Stable Heat Dissipation: The intelligent temperature controlled fan dissipates heat, reduces noise interference, and allows the power supply to output stably for a long time.
3. Wide Range Of Applications: Suitable for mobile phone and notebook computer maintenance, aging test, battery charging and discharging experiment, laboratory, etc.
4. Multiple Functions: Support output voltage and current change curve monitoring function. List waveform editing output, edit 10 groups of timing output. 4 groups of memory shortcut parameter call function.
5. Single Channel Output: Single channel digital DC power supply, stable output of low ripple and noise power supply, meeting high accuracy testing requirements.
Specification:
Item Type: DC Power Supply
Material: Iron
Uses: Aging test, battery charging, electronic product maintenance, military research and development, quality inspection, circuit function test, automotive circuit test, industrial production automation test, education and technical training, electronic component test and aging experiment, monitoring battery charging curve
Support Language: English
Model
SPE3051
SPE3102
SPE6102
SPE6053
Channel
Single channel output
Total Output Power
150W constant power output
200W constant output
300W constant output
Channel Output
0 30V 0 5A
0 30V 0 10A
0 60V 0 10A
0 60V 0 5A
Rated Output (0 celsius 40 celsius )
Voltage
0 30V
0 30V
0 60V
0 60V
Current
5A
10A
10A
5A
Power
150W
200W
200W
300W
Load Rectified Power
Voltage
less than 30mV
Current
less than 20mA
Power Regulation Rate
Voltage
less than 30mV
Current
less than 20mA
Set Resolution
Voltage
10mV
Current
1mA
Readback Resolution
Voltage
10mV
Current
1mA
Set Value Accuracy (25 celsius + 5 celsius )
Voltage
less than 0.1percent + 20mV
less than 0.1percent + 30mV
less than 0.1percent + 20mV
Current
less than 0.1percent + 10mA
Accuracy of Readback Value (25 celsius + 5 celsius )
Voltage
less than 0.1percent + 20mV
less than 0.1percent + 30mV
less than 0.1percent + 20mV
Current
less than 0.1percent + 10mA
Ripple And Noise
Voltage (Vp p)
less than 30mVp p
less than 50mVp p
less than 30mVp p
Voltage (rms)
less than 3mVrms
less than 5mVrms
less than 3mVrms
Current (rms)
less than 30mAp p
Output Temperature Coefficient (0 celsius 40 celsius )
Voltage
100ppm celsius
Current
200ppm celsius
Temperature Coefficient of Readback Value
Voltage
100ppm celsius
Current
200ppm celsius
Transient Recovery Time (50percent 100 percent Rated Load)
less than 1.0ms
Storage
4 sets of data
Operating Temperature
0 40 celsius
.
Package List:
1 x Power Supply1 x USB Cable1 x Plug1 x Fuse1 x Manual
Note:
1. Product grounding: This product is grounded through the grounding conductor of the power cord. To prevent electric shock, the grounding conductor must be connected to the ground. Before connecting to the input or output terminals of the product, make sure that the product is properly grounded.2. Pay attention to the ratings of all terminals: In order to prevent risks of fire or electric shock, please pay attention to all the ratings and marks of this product. Before connecting this product, please read the user manual of this product for further information about the ratings.3. Do not operate without the instrument cover: if the cover or panel has been removed, do not operate the product.4. Use appropriate fuses: Only use fuses that meet the specified type and rating of this product.5. Avoid contact with exposed circuits: When the product is powered, please do not touch the exposed contacts and components.6. When there is a suspicious failure, please do not operate: If you suspect that the product is damaged, please have it checked by qualified maintenance personnel.7. Provide good ventilation: Maintain good ventilation when using, and check the vents and fans regularly.8. Do not operate in a humid environment: In order to avoid risks of short circuit of the internal circuit of the instrument or electric shock, please do not operate the instrument in a humid environment.9. Do not operate in an flammable and explosive environment: In order to avoid damage to the instrument or person injury, please do not operate the instrument in an flammable and explosive environment.10. Keep the surface of the product clean and dry: To avoid dust or moisture in the air from affecting the performance of the instrument, please keep the surface of the product clean and dry.